      • natural, accurate - laboratory incubator
      • chamber volume 707 litres
      • temperature range from 5°C above ambient to 100°C
      • characterized by noiseless operation and fine air flow in the usable space
      • high operation comfort, precise temperature control and short chamber temperature equalization times after the door opening
      • high-quality and safe drying, heating and tempering of common laboratory materials in laboratory and industrial areas, suitable for safe processing of microbiological cultures
      • standard version with microprocessor control system Fuzzy logic, controls placed on a foil keyboard, process information displayed on LED display
      • wide selection of optional equipment and accessories
      • output for connecting a printer or PC
      • possibility of validation (IQ, OQ)

      Interior of stainless steel material No. 1.4301

      volume707 l
      depth520 mm
      width940 mm
      height1410 mm

      Tray

      standard equipment2 pcs
      storage area (w × d)920 × 485 mm
      racks19 max. number
      distance between guide rails70 mm

      Maximal weight of the load*)

      inside the oven130 kg/oven
      per tray50 kg/tray

      Door

      2 pcs

      External dimensions (including door and handle)

      depth790 mm
      diameter of the air branch outer / inner52/49 mm
      width1160 mm
      1910 (K)

      Package dimensions (three layers carton)

      depth860 mm
      width1230 mm
      depth2085 mm

      Weight

      brut240 kg
      nett215 kg

      Working temperature (beginning of the regulation)

      from 5 °C above ambient temp. to:100 °C

      Temperature accuracy according to DIN 12 880 T2 at working temperature with closed air flap and door

      time variation cca (±)<=0,2 °C
      space deviation cca (±)< 1,5 °C

      Time required to reach 37 °C with closed air flap and voltage 230 V

      59 min

      Heat emission at 37 °C

      85 W

      Air exchange speed at 37 °C

      5 per hour

      Electricity - mains 50/60 Hz

      max. power0,9 kW
      nominal voltage230 V
      current3,9 A
      power by stand by5 W

      *) Approx. 50 % of the tray area can be filled in a way a uniform air circulation is enabled inside the chamber. Note: All technical data are related to 22 °C ambient temperature and +-10 % voltage swing (if not specified).

      Changes in the design and make reserved.
      The values may differ depending on specific charge and media parameters.
Items have been added to cart.
One or more items could not be added to cart due to certain restrictions.
- Added to cart
- Can't add this product to the cart now. Please try again later.
- Quantity updated
- An error occurred. Please try again later.
Deleted from cart
- Can't delete this product from the cart at the moment. Please try again later.