PETRATECH KSA
PETRATECH KSA
Laboratory Equipment
0
INCUCELL 22 - ECO line
INCUCELL 22 - ECO line
INCUCELL 22 - ECO line
INCUCELL 22 - ECO line
INCUCELL 22 - ECO line

INCUCELL 22 - ECO line

0.00SAR

INCUCELL 22 - ECO line

Quantity
Add to Cart
Product Details
        • natural, accurate - laboratory incubator
        • chamber volume 22 litres
        • temperature range from 5°C above ambient to 100°C
        • characterized by noiseless operation and fine air flow in the usable space
        • high operation comfort, precise temperature control and short chamber temperature equalization times after the door opening
        • high-quality and safe drying, heating and tempering of common laboratory materials in laboratory and industrial areas, suitable for safe processing of microbiological cultures
        • standard version with microprocessor control system Fuzzy logic, controls placed on a foil keyboard, process information displayed on LED display
        • wide selection of optional equipment and accessories
        • output for connecting a printer or PC

        Interior of stainless steel material No. 1.4301

        volume22 l
        depth350 mm
        width240 mm
        height300 mm

        Tray

        standard equipment2 pcs
        storage area (w × d)185 × 265 mm
        racks4 max. number
        distance between guide rails60 mm

        Maximal weight of the load*)

        inside the oven25 kg/oven
        per tray10 kg/tray

        Door

        1 pcs

        External dimensions (including door and handle)

        depth560 mm
        diameter of the air branch outer / inner52/49 mm
        width406 mm
        610 (N)

        Package dimensions (three layers carton)

        depth720 mm
        width500 mm
        depth810 mm

        Weight

        brut36 kg
        nett31 kg

        Working temperature (beginning of the regulation)

        from 5 °C above ambient temp. to:100 °C

        Temperature accuracy according to DIN 12 880 T2 at working temperature with closed air flap and door

        time variation cca (±)0,4 °C
        space deviation cca (±)1,1 °C

        Time required to reach 37 °C with closed air flap and voltage 230 V

        70 min

        Heat emission at 37 °C

        20 W

        Air exchange speed at 37 °C

        4 per hour

        Electricity - mains 50/60 Hz

        max. power0,24 kW
        nominal voltage230 V
        current1,1 A
        power by stand by5 W

        *) Approx. 50 % of the tray area can be filled in a way a uniform air circulation is enabled inside the chamber. Note: All technical data are related to 22 °C ambient temperature and +-10 % voltage swing (if not specified).

        Changes in the design and make reserved.
        The values may differ depending on specific charge and media parameters.
        • possibility of validation (IQ, OQ)
Items have been added to cart.
One or more items could not be added to cart due to certain restrictions.
- Added to cart
- Can't add this product to the cart now. Please try again later.
- Quantity updated
- An error occurred. Please try again later.
Deleted from cart
- Can't delete this product from the cart at the moment. Please try again later.