PETRATECH KSA
PETRATECH KSA
Laboratory Equipment
0
INCUCELL 111- EVO line
INCUCELL 111- EVO line
INCUCELL 111- EVO line
INCUCELL 111- EVO line
INCUCELL 111- EVO line

INCUCELL 111- EVO line

0.00SAR

INCUCELL 111 - EVO line

Quantity
Add to Cart
Product Details
        • natural, accurate - laboratory incubator
        • chamber volume 111 litres
        • temperature range from 5°C above ambient to 100°C
        • characterized by noiseless operation and fine air flow in the usable space
        • high operation comfort, precise temperature control and short chamber temperature equalization times after the door opening
        • high-quality and safe drying, heating and tempering of common laboratory materials in laboratory and industrial areas, suitable for safe processing of microbiological cultures
        • standard version with microprocessor control system Fuzzy logic, controls placed on a foil keyboard, process information displayed on LED display
        • wide selection of optional equipment and accessories
        • output for connecting a printer or PC
        • possibility of validation (IQ, OQ)

        Interior of stainless steel material No. 1.4301

        volume111 l
        depth370 mm
        width540 mm
        height530 mm

        Tray

        standard equipment2 pcs
        storage area (w × d)520 × 335 mm
        racks7 max. number
        distance between guide rails70 mm

        Maximal weight of the load*)

        inside the oven50 kg/oven
        per tray20 kg/tray

        Door

        1 pcs

        External dimensions (including door and handle)

        depth680 mm
        diameter of the air branch outer / inner52/49 mm
        width760 mm
        860 (N)

        Package dimensions (three layers carton)

        depth750 mm
        width830 mm
        depth1060 mm

        Weight

        brut87 kg
        nett75 kg

        Working temperature (beginning of the regulation)

        from 5 °C above ambient temp. to:100 °C

        Temperature accuracy according to DIN 12 880 T2 at working temperature with closed air flap and door

        time variation cca (±)<=0,2 °C
        space deviation cca (±)< 0,5 °C

        Time required to reach 37 °C with closed air flap and voltage 230 V

        57 min

        Heat emission at 37 °C

        45 W

        Air exchange speed at 37 °C

        5 per hour

        Electricity - mains 50/60 Hz

        max. power0,3 kW
        nominal voltage230 V
        current1,3 A
        power by stand by5 W

        *) Approx. 50 % of the tray area can be filled in a way a uniform air circulation is enabled inside the chamber. Note: All technical data are related to 22 °C ambient temperature and +-10 % voltage swing (if not specified).

        Changes in the design and make reserved.
        The values may differ depending on specific charge and media parameters.
Items have been added to cart.
One or more items could not be added to cart due to certain restrictions.
- Added to cart
- Can't add this product to the cart now. Please try again later.
- Quantity updated
- An error occurred. Please try again later.
Deleted from cart
- Can't delete this product from the cart at the moment. Please try again later.