FRIOCELL 55 - ECO line
0.00SAR
FRIOCELL 55 - ECO line
Product Details
- precise, adaptable to nature, economical - laboratory incubator
- chamber volume 55 litres
- temperature range: 0°C to 100°C
- patented cooling system (ecological working medium R134a) offers accurate and fast simulation of natural processes and reduces the risk of evaporation of samples, the devices may be completed with various types of inner chamber lighting
- high operation comfort, precise temperature control and the possibility of achieving extremely short times of temperature changes as well as short times of temperature equalization in the chamber after the door opening; standard equipment also includes inner glass door and possibility of fan speed regulation
- suitable for demanding and accurate specimen culture testing and processes
- wide selection of optional equipment and accessories
- output for connecting a printer or PC
- possibility of validation (IQ, OQ)
Inner dimensions - Chamber, stainless steelvolume 55 l depth 370 mm width 400 mm height 350 mm
Volume of chamber space89 l (aprox.)
Trays, stainless steel *)Min. distance between trays 70 mm number 4/2 max./usual Storage area (w × d) 380 × 335 mm
Number of outer metal doorsnumber 1 pcs
Number of inner glass doorsnumber 1 pcs
Admissible weight of traystogether inside the oven 50 kg per 1 tray 20 kg
Electricity dataMax. power 700 W IP 20 mains 50/60Hz 230 V
Temperature dataCooling/down time from 22 °C to 10 °C < 21 min Heating/up time to 37 °C from the ambient temperature 11 min Working temperature from 0,0 to 100 °C Temperature accuracy - in time 0,2 ± °C Temperature accuracy - in space at 10 °C 0,5 ± °C
Recovery time after 30 s door openat 37 °C 5 min at 50 °C 6 min
Heat emissionat 37 °C 55 W
Outer dimensions, incl. door and handle, Feet (N) or Rollers (K)depth 650 mm width 620 mm height 875 (N) mm
Weightbrut 102 kg nett 83 kg
Changes in the design and make reserved.
The values may differ depending on specific charge and media parameters
- precise, adaptable to nature, economical - laboratory incubator
- chamber volume 55 litres
- temperature range: 0°C to 100°C
- patented cooling system (ecological working medium R134a) offers accurate and fast simulation of natural processes and reduces the risk of evaporation of samples, the devices may be completed with various types of inner chamber lighting
- high operation comfort, precise temperature control and the possibility of achieving extremely short times of temperature changes as well as short times of temperature equalization in the chamber after the door opening; standard equipment also includes inner glass door and possibility of fan speed regulation
- suitable for demanding and accurate specimen culture testing and processes
- wide selection of optional equipment and accessories
- output for connecting a printer or PC
- possibility of validation (IQ, OQ)
volume | 55 l |
depth | 370 mm |
width | 400 mm |
height | 350 mm |
89 l (aprox.) |
Min. distance between trays | 70 mm |
number | 4/2 max./usual |
Storage area (w × d) | 380 × 335 mm |
number | 1 pcs |
number | 1 pcs |
together inside the oven | 50 kg |
per 1 tray | 20 kg |
Max. power | 700 W |
IP 20 | |
mains 50/60Hz | 230 V |
Cooling/down time from 22 °C to 10 °C | < 21 min |
Heating/up time to 37 °C from the ambient temperature | 11 min |
Working temperature from 0,0 to | 100 °C |
Temperature accuracy - in time | 0,2 ± °C |
Temperature accuracy - in space at 10 °C | 0,5 ± °C |
at 37 °C | 5 min |
at 50 °C | 6 min |
at 37 °C | 55 W |
depth | 650 mm |
width | 620 mm |
height | 875 (N) mm |
brut | 102 kg |
nett | 83 kg |
The values may differ depending on specific charge and media parameters
*) Approx. 50 % of the tray area can be filled in a way a uniform air circulation is enabled inside the chamber.Note: All technical data are related to 22 °C of ambient temperature and ±10 % voltage swing rate ventilator 100 %, defrost off, lighting off.
*) Approx. 50 % of the tray area can be filled in a way a uniform air circulation is enabled inside the chamber.Note: All technical data are related to 22 °C of ambient temperature and ±10 % voltage swing rate ventilator 100 %, defrost off, lighting off.