DUROCELL 22 - ECO line
DUROCELL 22 - ECO line
DUROCELL 22 - ECO line
DUROCELL 22 - ECO line
DUROCELL 22 - ECO line

DUROCELL 22 - ECO line

0.00SAR
Product Details
    • highly resistant laboratory drying oven
    • chamber volume 22 litres
    • temperature range from 5°C above ambient to 125°C
    • natural fine airflow in the work area, noiseless operation
    • high-quality and safe drying, heating and tempering of laboratory materials in the laboratory and industrial areas
    • high operation comfort, precise temperature control and short chamber temperature equalization times after the door opening
    • wide selection of optional equipment and accessories
    • output for connecting a printer or PC
    • possibility of validation (IQ, OQ)

    Interior of stainless steel material No. 1.4301

    volume22 l
    depth350 mm
    width240 mm
    height300 mm

    Trays

    standard equipment2 pcs
    storage area (w × d)185×265 mm
    racks4 max. no
    distance between guide rails60 mm

    Maximal weight of the load*)

    inside the oven25 kg/oven
    per tray10 kg/tray

    Door

    1 pcs

    External dimensions (including door and handle)

    depth560 mm
    diameter of the air branch outer/inner52/49 mm
    width406 mm
    height (inclusive foots - N)610 (N) mm

    Package dimensions (three layers carton)

    depth720 mm
    width500 mm
    depth810 mm

    Weight

    brut36 kg
    nett31 kg

    Working temperature (beginning of the regulation)

    from 5 °C above ambient temp. to:125 °C

    Temperature accuracy according to DIN 12 880 T2, at working temperature with closed air flap and door

    time variation cca (±)1 °C
    space deviation cca (±) % of the reached temperature2,7 %

    Time required to reach 100 °C with closed air flap and voltage 230 V

    34 min

    Heat emission at 100 °C

    140 W

    Air exchange speed at 100 °C

    6 per hour

    Electricity – mains 50/60 Hz

    max. power input0,9 kW
    nominal voltage230 V
    current4 A
    input in stand by mode5 W

    Note: All technical data are related to 22 °C of ambient temperature and ±10 % voltage swing rate ventilator 100 %, defrost off, lighting off.

    Changes in the design and make reserved.
    The values may differ depending on specific charge and media parameters.
Items have been added to cart.
One or more items could not be added to cart due to certain restrictions.
- Added to cart
- Can't add this product to the cart now. Please try again later.
- Quantity updated
- An error occurred. Please try again later.
Deleted from cart
- Can't delete this product from the cart at the moment. Please try again later.