PETRATECH KSA
PETRATECH KSA
Laboratory Equipment
0
Automatic Device for Multichannel Pipette Calibration [d]: 0.01 mg/52 g
Automatic Device for Multichannel Pipette Calibration [d]: 0.01 mg/52 g
Automatic Device for Multichannel Pipette Calibration [d]: 0.01 mg/52 g
Automatic Device for Multichannel Pipette Calibration [d]: 0.01 mg/52 g
Automatic Device for Multichannel Pipette Calibration [d]: 0.01 mg/52 g

Automatic Device for Multichannel Pipette Calibration [d]: 0.01 mg/52 g

0.00SAR

AP-12.5YAutomatic Device for Multichannel Pipette Calibration

Maximum capacity [Max]: 52 g
Readability [d]: 0.01 mg

Quantity
Add to Cart
Product Details

AP-12.5Y Automatic Device for Multichannel Pipette Calibration
 
 
The AP-12.5Y is designed to calibrate multichannel pipettes starting at 10 μl. The device features a readability [d] of 0.01 mg and can calibrate up to 12-channel fixed-volume and variable-volume pipettes.
 
Because the pipette calibration on the AP-12.5Y is fully automatic, it is four times faster. The calibration procedure for a 12-channel pipette takes less than 20 minutes, not six hours, on this instrument.
 
When purchasing the AP-12.5Y, you get:
  • two calibrated sensors: THB S and THB W,
  • two weighing pans: standard, and for balance test and calibration,
  • two pumps: a single-channel pump and a four-channel pump
 
The ergonomic design of the AP-12.5Y makes it possible to empty weighing vessels, and their overfilling is signalled by Ambient Light. When calibrating a multichannel pipette, a four-channel pump is used to simultaneously remove water from four vessels, greatly reducing the time required for pipette calibration.
 
After emptying a 12-channel pipette, the AP-12.5Y checks all channels in a single cycle. In addition to a database of pipette calibration reports, the AP-12.5Y includes a database of pipettes that is editable and contains maximum permissible error values according to ISO 8655. The report database, in turn, contains measurements and error values calculated for individual points and volumes. The user determines the format and content of the reports.
 
The AP-12.5Y monitors the ambient conditions using calibrated sensors: THB S (ambient conditions measurement) and THB W (liquid temperature measurement), in accordance with ISO 8655. To calibrate the device with mass standards, the weighing pan must be replaced with a pan dedicated to checking and calibrating the balance (both are included in the standard equipment).
 
The AP-12.5Y can calibrate not only 12-channel pipettes, but also single-channel pipettes. 

Maximum capacity [Max]

52

 g

Readability [d]

0.01

 mg

Tare range

-52

 g

Standard repeatability [5% Max]

5

 µg

Standard repeatability [Max]

10

 µg

Standard minimum weight (USP)

10

 mg

Standard minimum weight (U=1%, k="2)

1

 mg

Linearity

±0.03

 mg

Stabilization time

4

 s

Adjustment

internal (automatic)

 

Typical measurement time for a 12-channel pipette with constant volume,
according to ISO 8655 (for d="10" µg)*

under 20 minutes

 

Typical measurement time for a 12-channel pipette with variable volume,
according to ISO 8655 (for d="10µ"g)*

under 60 minutes

 

Relative humidity

20% — 80%

 

Display

10″ touchscreen

 

Weighing pan dimensions

ø26 + automat

 

Packaging dimensions

605×560×775

 mm

Net weight

17

 kg

Gross weight

30

 kg

Communication interface

USB-A ×2, USB-C, HDMI, Ethernet, Wi-Fi®, Hotspot

 

Operating temperature

+10 — +40

 °C

Operating temperature change rate

±0.3°C/1h (±1°C/8h)

 

Relative humidity change rate

±1%/h (±4%/8h)

 



































































Items have been added to cart.
One or more items could not be added to cart due to certain restrictions.
- Added to cart
- Can't add this product to the cart now. Please try again later.
- Quantity updated
- An error occurred. Please try again later.
Deleted from cart
- Can't delete this product from the cart at the moment. Please try again later.