PETRATECH KSA
PETRATECH KSA
Laboratory Equipment
0
INCUCELL V 444- EVO line
INCUCELL V 444- EVO line
INCUCELL V 444- EVO line
INCUCELL V 444- EVO line
INCUCELL V 444- EVO line

INCUCELL V 404- EVO line

0.00SAR

INCUCELL V 404 - EVO line

Quantity
Add to Cart
Product Details
            • natural, accurate - laboratory incubator
            • chamber volume 404 litres
            • temperature range from 10°C above ambient to 100°C
            • characterized by noiseless operation and fine air flow in the usable space
            • high operation comfort, precise temperature control and short chamber temperature equalization times after the door opening
            • high-quality and safe drying, heating and tempering of common laboratory materials in laboratory and industrial areas, suitable for safe processing of microbiological cultures
            • standard version with microprocessor control system Fuzzy logic, controls placed on a foil keyboard, process information displayed on LED display
            • wide selection of optional equipment and accessories
            • output for connecting a printer or PC
            • possibility of validation (IQ, OQ)

            Interior of stainless steel material No. 1.4301

            volume404 l
            width540 mm
            height1410 mm

            Tray

            standard equipment2 pcs
            storage area (w × d)520 × 485 mm
            racks19 max. number
            distance between guide rails70 mm

            Maximal weight of the load *)

            inside the oven100 kg/oven
            per tray30 kg/tray

            Door

            1 pcs

            External dimensions (including door and handle)

            depth790 mm
            diameter of the air branch outer/inner52/49 mm
            width760 mm
            1910 (K)

            Package dimensions (three layers carton)

            depth860 mm
            width830 mm
            depth2085 mm

            Weight

            brut175 kg
            nett150 kg

            Working temperature (beginning of the regulation)

            from 10 °C above ambient temp. to:100 °C

            Temperature accuracy according to DIN 12 880 T2 at working temperature with closed air flap and door

            time variation cca (±)<=0,2 °C
            space deviation cca (±)<=0,8 °C

            Time required to reach 37 °C with closed air flap and voltage 230 V

            38 min

            Heat emission at 37 °C

            115 W

            Air exchange speed at 37 °C

            18 per hour

            Electricity - mains 50/60 Hz

            max. power1,3 kW
            nominal voltage230 V
            current5,6 A
            power by stand by5 W

            *) Approx. 50 % of the tray area can be filled in a way a uniform air circulation is enabled inside the chamber. Note: All technical data are related to 22 °C of ambient temperature and ±10 % voltage swing rate ventilator 100 %, defrost off, lighting off.

            Changes in the design and make reserved.
            The values may differ depending on specific charge and media parameters.
Items have been added to cart.
One or more items could not be added to cart due to certain restrictions.
- Added to cart
- Can't add this product to the cart now. Please try again later.
- Quantity updated
- An error occurred. Please try again later.
Deleted from cart
- Can't delete this product from the cart at the moment. Please try again later.