PETRATECH KSA
PETRATECH KSA
Laboratory Equipment
0
INCUCELL V 222- EVO line
INCUCELL V 222- EVO line
INCUCELL V 222- EVO line
INCUCELL V 222- EVO line
INCUCELL V 222- EVO line

INCUCELL V 222- EVO line

0.00SAR

INCUCELL V 222 - EVO line

Quantity
Add to Cart
Product Details
          • natural, accurate - laboratory incubator
          • chamber volume 222 litres
          • temperature range from 10°C above ambient to 100°C
          • characterized by noiseless operation and fine air flow in the usable space
          • high operation comfort, precise temperature control and short chamber temperature equalization times after the door opening
          • high-quality and safe drying, heating and tempering of common laboratory materials in laboratory and industrial areas, suitable for safe processing of microbiological cultures
          • standard version with microprocessor control system Fuzzy logic, controls placed on a foil keyboard, process information displayed on LED display
          • wide selection of optional equipment and accessories
          • output for connecting a printer or PC
          • possibility of validation (IQ, OQ)

          Interior of stainless steel material No. 1.4301

          volume222 l
          width540 mm
          height760 mm

          Tray

          standard equipment2 pcs
          storage area (w × d)520 × 485 mm
          racks10 max. number
          distance between guide rails70 mm

          Maximal weight of the load *)

          inside the oven70 kg/oven
          per tray30 kg/tray

          Door

          1 pcs

          External dimensions (including door and handle)

          depth830 mm
          diameter of the air branch outer/inner52/49 mm
          width760 mm
          1090 (N)

          Package dimensions (three layers carton)

          depth890 mm
          width820 mm
          depth1260 mm

          Weight

          brut116 kg
          nett100 kg

          Working temperature (beginning of the regulation)

          from 10 °C above ambient temp. to:100 °C

          Temperature accuracy according to DIN 12 880 T2 at working temperature with closed air flap and door

          time variation cca (±)<=0,2 °C
          space deviation cca (±)<=0,3 °C

          Time required to reach 37 °C with closed air flap and voltage 230 V

          66 min

          Heat emission at 37 °C

          95 W

          Air exchange speed at 37 °C

          24 per hour

          Electricity - mains 50/60 Hz

          max. power0,7 kW
          nominal voltage230 V
          current3 A
          power by stand by5 W

          *) Approx. 50 % of the tray area can be filled in a way a uniform air circulation is enabled inside the chamber. Note: All technical data are related to 22 °C of ambient temperature and ±10 % voltage swing rate ventilator 100 %, defrost off, lighting off.

          Changes in the design and make reserved.
          The values may differ depending on specific charge and media parameters.
Items have been added to cart.
One or more items could not be added to cart due to certain restrictions.
- Added to cart
- Can't add this product to the cart now. Please try again later.
- Quantity updated
- An error occurred. Please try again later.
Deleted from cart
- Can't delete this product from the cart at the moment. Please try again later.