CLIMACELL 222 - ECO line
0.00SAR
CLIMACELL 222 - ECO line
Product Details
- laboratory incubator – it always creates the right climate
- chamber volume 222 litres
- temperature range: from 0°C to 100°C without humidity, from 10° C to 90° C with humidity
- patented cooling system (environment-friendly working medium R 134a) and air flow in the chamber ensure fast and accurate distribution of the selected temperature and humidity in the chamber and thus the ideal process of sample heating and reduction of moisture condensation in the chamber
- offers high operation comfort, precise temperature control, possibility of achieving extremely short times of temperature changes and short times of temperature and humidity equalization in the chamber after the door opening
- suitable for use in research on germs, plant or tissue cultures, insects, stability tests, etc.
- comfortable design with multi-processor Fuzzy logic control system, controls placed on a foil keyboard, process information displayed on LED display.
- wide selection of optional equipment and accessories
- output for connecting a printer or PC
- possibility of validation (IQ, OQ)
Interior of stainless steel material
volume 222 l depth 520 mm width 540 mm height 760 mm
volume | 222 l |
depth | 520 mm |
width | 540 mm |
height | 760 mm |
Volume of chamber space
299 l (aprox.)
299 l (aprox.) |
Trays, stainless steel *)
Min. distance between trays 70 mm number usual 2 pcs number max. 10 pcs Storage area (w × d) 520 × 485 mm
Min. distance between trays | 70 mm |
number usual | 2 pcs |
number max. | 10 pcs |
Storage area (w × d) | 520 × 485 mm |
Number of outer metal doors
number 1 pcs
number | 1 pcs |
Number of inner glass doors
number 1 pcs
number | 1 pcs |
Admissible weight of trays
together inside the oven 70 kg per 1 tray 30 kg
together inside the oven | 70 kg |
per 1 tray | 30 kg |
Electricity data
Max. power 1850 W IP 20 mains 50/60Hz 230 V
Max. power | 1850 W |
IP 20 | |
mains 50/60Hz | 230 V |
Temperature data
Cooling/down time from 22 °C to 10 °C < 17 min Heating/up time to 37 °C from the ambient temperature 11 min Working temperature from 0,0 to 100 °C Working temperature from -20 to 100 °C Temperature accuracy - in time 0,2 ± °C Temperature accuracy in time at 10 °C < 0,5 ±°C Temperature accuracy in time at 37 °C < 0,5 ±°C
Cooling/down time from 22 °C to 10 °C | < 17 min |
Heating/up time to 37 °C from the ambient temperature | 11 min |
Working temperature from 0,0 to | 100 °C |
Working temperature from -20 to | 100 °C |
Temperature accuracy - in time | 0,2 ± °C |
Temperature accuracy in time at 10 °C | < 0,5 ±°C |
Temperature accuracy in time at 37 °C | < 0,5 ±°C |
Recovery time after 30 sec. door open according DIN 12 880
at 37 °C 3 min at 50 °C 6 min
at 37 °C | 3 min |
at 50 °C | 6 min |
Relative humidity
range 10–98 %
range | 10–98 % |
Heat emission
at 37 °C 63 W
at 37 °C | 63 W |
Outer dimensions (incl. Door and handle, and Rollers)
depth 895 mm width 760 mm height 1370 mm
depth | 895 mm |
width | 760 mm |
height | 1370 mm |
Weight
brut cca 184 kg nett cca 135 kg
*) Approx. 50 % of the tray area can be filled in a way a uniform air circulation is enabled inside the chamber.Note: All technical data are related to 22 °C of ambient temperature and ±10 % voltage swing rate ventilator 100 %, defrost off, lighting off.
Changes in the design and make reserved.
The values may differ depending on specific charge and media parameters.
brut cca | 184 kg |
nett cca | 135 kg |
*) Approx. 50 % of the tray area can be filled in a way a uniform air circulation is enabled inside the chamber.Note: All technical data are related to 22 °C of ambient temperature and ±10 % voltage swing rate ventilator 100 %, defrost off, lighting off.
Changes in the design and make reserved.The values may differ depending on specific charge and media parameters.